USERS’ INSTALLATION
OPERATION and
MAINTENANCE MANUAL
45
45
-
-
DVFS28N
DVFS28N
-
-
2
2
Optima 45
Optima 45
SN 5170 AND UP
SN 5170 AND UP
For use with Natural Gas or Propane*
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
WHAT TO DO IF YOU SMELL GAS:
* Do not try to light any appliance.
* Do not touch any electrical switch; do not use
any phone in your building.
* Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
* If you cannot reach your gas supplier, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.
WARNING: If the information in this manual is
not followed exactly, fire or explosion may result
causing property damage, personal injury or loss
of life.
Installer: Please leave this manual with the appliance owner for future reference
200-0185
September 2010
This appliance may be installed in an after-market,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by local
codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a
certified kit is used.
7116 Beatty Dr
Mission, BC V2V 6B4
Canada
*Conversion Kit Required for Propane Use
Vista de página 0
1 2 3 4 5 6 ... 47 48

Resumo do Conteúdo

Página 1 - MAINTENANCE MANUAL

USERS’ INSTALLATION OPERATION and MAINTENANCE MANUAL 4545--DVFS28NDVFS28N--22 Optima 45Optima 45 SN 5170 AND UPSN 5170 AND UP For use with Natural

Página 2

45-DVFS28N-2 10 LOCATING GAS HEATER This appliance must be installed in a location that is free of plumbing, electrical

Página 3 - INTRODUCTION

45-DVFS28N-2 11 ALLOWABLE TERMINATION LOCATIONS Canadian Installations (1) US Installations (2) Canadian Installations (1) US

Página 4 - TABLE OF CONTENTS

45-DVFS28N-2 12 APPROVED VENT COMPONENTS For best and safe venting performance, here are some general venting rules:  Use only Arc

Página 5 - SAFETY

45-DVFS28N-2 13 VENTING CHART The appliance will not function without being connected to a proper venting system. This appliance may

Página 6 - HIGH ALTITUDE INSTALLATION

45-DVFS28N-2 14 1. Maintain 1” (25 mm) clearance (air space) to combustibles when passing through ceilings walls, roof, enclosures

Página 7 - GAS CONNECTIONS

45-DVFS28N-2 15 NOTE:  Galvanized pipe is desirable above the roofline due to its higher corrosion resistance. Continu

Página 8 - APPLIANCE DESCRIPTION

45-DVFS28N-2 16 NOTES: This Vent Kit must be installed directly onto the flue outlet of the heater. Maintain a minimum of 1” (25m

Página 9 - TOP VIEW

45-DVFS28N-2 17 VENTING - BELOW GRADE USING FLEXIBLE DIRECT VENT SYSTEMS INSTALLATION PROCEDURES FOR ARCHGARD SNORKEL KIT (999-DV-STC

Página 10 - VENT TERMINATION LOCATIONS

45-DVFS28N-2 18 Measure wall thickness from the back of the fireplace standoffs to inside mounting surface of the termination cap. If

Página 11

45-DVFS28N-2 19 VENTING - HORIZONTALLY USING SIMPSON DURA-VENT DIRECT VENT SYSTEMS 1. Set the Optima 45 in its desired locati

Página 12 - VENTING CONNECTION

5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.3 by adding the following additional requirements: (a) For all side wall horizontally vent

Página 13

45-DVFS28N-2 20 VENTING - HORIZONTALLY USING SIMPSON DURA-VENT DIRECT VENT SYSTEMS INSTALLATION PROCEDURES FOR SIMPSON DURA-VENT DIRE

Página 14 - 10” (254mm)

45-DVFS28N-2 21 SNORKEL TERMINATIONS: For installations requiring a vertical rise on the exterior of the building, 14” (3

Página 15

45-DVFS28N-2 22 LOG PLACEMENT Archgard chooses ceramic fiber logs for use in the Optima 45. The logs are designed to give a re-alis

Página 16 - 11” (279 mm)

45-DVFS28N-2 23 LOG PLACEMENT - Continued LOG 74 BACK LOG RESTS REAR LOG RESTS The rear logs must be placed on top of the log rests

Página 17 - Drainage

45-DVFS28N-2 24 LOG PLACEMENT - Continued LOG #1 Place log number 1 on top of the left rear log rest with the two pins aligned with

Página 18

45-DVFS28N-2 25 LOG PLACEMENT - Continued LOG #3 LOG #4 Place log number 3 on the two right pins so they align with the holes in the

Página 19

45-DVFS28N-2 26 LOG PLACEMENT - Continued LOG #5 Place log number 5 so the bottom left of the log sits on the burner directly behind

Página 20

45-DVFS28N-2 27 The Optima 45 has optional Ceramic Brick Panels or Reflective Glass Panels available. They can be purchased through

Página 21

45-DVFS28N-2 28 If a wall-mounted switch or a wall-mounted thermostat is desired, Archgard recommends that the device be wired as sho

Página 22 - LOG PLACEMENT

45-DVFS28N-2 29 INITIAL OPERATION 1. Check that the appliance is properly vented and connected to the gas supply. 2. Check that the

Página 23 - REAR LOG RESTS

INTRODUCTION Congratulations on choosing an Archgard fireplace! The Optima 45 is one of the most advanced direct vent fireplace heaters available. It

Página 24

45-DVFS28N-2 30 This appliance has a pilot which must be ignited using the sparker located next to the appliance valve controls. When

Página 25

45-DVFS28N-2 31 1. Set the thermostat to the lowest setting and turn the remote switch to “OFF”. 2. Turn off all electric power to

Página 26

45-DVFS28N-2 32 WARNING: Do not attempt to remove the glass door when the appliance is hot. Removing the Glass Door 1. Open both sid

Página 27

45-DVFS28N-2 33 TROUBLESHOOTING SYMPTOM ACTION Pilot will not light after pressing the sparker many times. 1. When lighting the appl

Página 28 - PILOT ASSEMBLY

45-DVFS28N-2 34 TROUBLESHOOTING Continued SYMPTOM ACTION The main burner does not turn on with the pilot lit. Cont... 3. Check to ma

Página 29 - FINAL INSTALLATION CHECK

45-DVFS28N-2 35 Regularly:  Frequent cleaning of the ceramic glass is required. Archgard recommends using a good quality “gas fire

Página 30 - FIRST FIRE

45-DVFS28N-2 36 Before servicing, read the Terms and Conditions of the Archgard Warranty at the back of the manual. Contact the Autho

Página 31 - 303-0001

45-DVFS28N-2 37 ADJUSTING PRIMARY AIR 1. Remove the glass door. Follow GLASS DOOR REMOVAL instructions within this manua

Página 32 - To open the door

45-DVFS28N-2 38 Thermopile Burner Ports Electrode Thermocouple 1. Remove the control panel. 2. The pressure test taps are located on

Página 33 - TROUBLESHOOTING

45-DVFS28N-2 39 REPLACING CONVECTION BLOWER Caution: Label all wires prior to disconnection when servicing controls. Wiring

Página 34 - TROUBLESHOOTING Continued

TABLE OF CONTENTS Caution and Safety Instructions 5 Appliance Certification / Installation Codes / Specifications / High Altitude Installation 6 Gas C

Página 35

45-DVFS28N-2 40 VALVE TRAY ASSEMBLY Item # Item Description Qty Unit A 308-0013 Valve NOVA SIT 820 (0.820.652) Natural Gas

Página 36 - SERVICING UNDER WARRANTY

45-DVFS28N-2 41 PARTS LIST - Ceramic Logs and Burner Pan Item # Item Description Qty Unit 310-6450-1 FiberFlame Log #1 1 EA 310

Página 37 - CHANGING MAIN BURNER ORIFICE

45-DVFS28N-2 42 REPLACEMENT PARTS LIST ARCHGARD OPTIMA 45-3 Item # Item Description Qty Unit 200-0185 Owner’s Manual 1 EA 300-0

Página 38 - CONVERTIBLE PILOT ORIFICE

This Limited Warranty is made by ARCHGARD INDUSTRIES LTD., hereinafter referred to as “Archgard”. Archgard warrants to the original purchaser of an

Página 39 - WIRING DIAGRAM

45-DVFS28N-2 44 FREQUENTLY ASKED QUESTIONS Listed below are some frequently asked questions regarding your Archgard Gas Fireplace. If

Página 41

POSTAGFOLD DOWN AT LINE FOLD DOWN AT LINE & TAPE CLOSED CUT ALONG LINE CUT ALONG LINE CUT ALONG LINE WARRANTY REGISTRATION ARCHGARD INDUSTRIES LT

Página 43

Archgard Industries Ltd. 7116 Beatty Drive Mission, B.C. V2V 6B4 Canada Website: www.archgard.com

Página 44 - FREQUENTLY ASKED QUESTIONS

45-DVFS28N-2 5 CAUTION FOR YOUR SAFETY - Do not install or operate your Archgard Optima 45 Direct Vent Gas Fireplace

Página 45

45-DVFS28N-2 6 SPECIFICATIONS Natural Gas (NG) Propane (LP) Manifold Pressure 1.6 - 3.5 in. W.C. (0.4 - 0.9 kPa) 6.3 - 10.0 in. W.

Página 46 - ARCHGARD INDUSTRIES LTD

45-DVFS28N-2 7 Before connecting the appliance to the gas supply line, double check that the appliance you have purchased is

Página 47

45-DVFS28N-2 8 APPLIANCE DIMENSIONS APPLIANCE DESCRIPTION MAIN CONTROL PANEL UPPER LOUVERS GLASS DOOR LOWER LOUVERS DIMENSIONS A

Página 48 - Archgard Industries Ltd

45-DVFS28N-2 9 DIMENSIONS AND CLEARANCES ALCOVE INSTALLATION * Side and back clearances for the alcove installation is the same as t